Implemented notifications:
loop1Alarm
initAlarm
acoAlarm
locAlarm
remotePowerFailureAlarm
resetAlarm
linkIntAlarm
confEr03Alarm
confEr04Alarm
confEr05Alarm
bertAlarm
loswAAlarm
loswBAlarm
berAAlarm
berABlarm
8.2.16 Schmid MIB
The Schmid MIB contains vendor-specific hardware identifiers (called the model
codes) for Schmid DSL modems. The model code can be read as sysObjectID
in the system group of mib-2.
Implemented data structures:
schmidGeneralWatsonModelCodes group
8.2.17 Watson MIB
The Watson MIB contains vendor-specific data structures for Watson modems.
Implemented data structures:
watsonSpecificCardTable to configure
- Card Reset
- CoS Scheduling Policy
- Cardmode
- Bridgemode
watsonSpecificIfConfTable to configure
- interface-specific CoS features (Rate limiting, priority source)
- doubletagging
- MAC Defect Signaling